Artisan reads Roastwarden over its Modbus slave, with a setup file to load.
If you roast with Artisan, you can keep its screen while you try Roastwarden. Roastwarden's server speaks Modbus TCP as a roaster would, and Artisan connects to it like any Modbus roaster: Artisan draws and records the roast it reads, and Roastwarden records the same roast with its own alarms, control and history. Nothing in Artisan is lost: your profiles, alarms and palettes stay as they were. It is off unless you switch it on.
Switching it on
The server opens the slave when ROASTWARDEN_MODBUS_ADDR is set:
| Variable | Default | What it does |
|---|---|---|
ROASTWARDEN_MODBUS_ADDR | unset (off) | Where the slave listens: 0.0.0.0:502 (502 is Modbus's port and Artisan's default) |
ROASTWARDEN_MODBUS_DEVICE_ID | the one real roaster | The roaster it serves. Unset: the one real roaster heard in the last minute; the virtual roasters never count, so with none or two real roasters it serves nothing and says why |
ROASTWARDEN_MODBUS_WRITES | off | on: Artisan's sliders become commands (below). Off: every write is refused |
With the compose file, uncomment the two lines it has for it (the environment line and the port) and restart:
ports:
- "8080:8080"
- "502:502" # Artisan as a screen (docs/artisan-screen.md)
environment:
- ROASTWARDEN_MODBUS_ADDR=0.0.0.0:502
The container runs as an ordinary user; Docker lets a container's own network open port 502
anyway. If the log says the port could not be opened (another engine, or the host's network),
use a high port on both sides ("1502:1502" and 0.0.0.0:1502); the setup file follows it.
Modbus has no password. Anyone who reaches the port reads the roaster, and with writes on can command it, through the same gate as the dashboard (the roaster's control level, its outputs' ranges, its fan floor; see roaster setup). Keep the port on the roaster's LAN, never forward it. Every write is in the audit log either way (below).
Connecting Artisan
- Get the setup file: Settings → About → Artisan screen → Setup for Artisan (.aset), or
roast artisan-screen --aset Roastwarden.aset --host <the server's LAN address>. The server fills in its own address (the one the browser orroastused;--hostwhen Artisan reaches it by another), the slave's port and the unit (the dashboard's °C/°F;--fahrenheit). Without the server at hand, the compose bundle has the same file asartisan/Roastwarden.asetwithhost=SERVER_ADDRESS: put the address in that line. - In Artisan: Help → Load Settings…, pick the file. It sets the device (Modbus), the connection, the four inputs, the extra curves and the unit, and leaves the rest of Artisan as it was (profiles, alarms, palettes). Help → Save Settings first keeps a copy of the old ones.
- Press ON. BT and ET are drawn at once, with Heater and Fan as extra curves (their LCDs on). Press START with Roastwarden's CHARGE to record the roast in Artisan too; the two records are independent.
roast artisan-screen (and roast status, and About) say whether the slave is on, the roaster
it serves (or why none), read-only or with writes, and when Artisan last read and from where.
What Artisan reads
The slave serves the "Roastwarden Standard" map (the Modbus TCP section of the hardware integration guide): input registers 0–7, function code 4, float32 with the high word first. The setup reads them in one block a second:
| Artisan | Register | Type |
|---|---|---|
| BT (input 1) | 0–1 | float32, °C (Artisan converts for °F) |
| ET (input 2) | 2–3 | float32, °C |
| Heater (extra device MODBUS_34, input 3) | 6 | whole %, no conversion |
| Fan (MODBUS_34, input 4) | 7 | whole %, no conversion |
The holding registers read back what the roaster reports now (setpoint, fan, heater, mode, heater enable). While the roaster is silent (nothing for 10 s), or there is no roaster to serve, a read is answered "gateway target failed to respond": Artisan draws a gap (-1) and notes "Modbus Communication Error" rather than a line at 0 °C, and picks up again by itself.
Control from Artisan (writes on)
With ROASTWARDEN_MODBUS_WRITES=on the setup file also has two sliders: Air writes the fan
(holding register 2) and Burner switches the heater on and writes its % (registers 5 and 3,
writeSingle(1,5,1);writeSingle(1,3,{}): on the firmware a heater % does nothing while the
heater is off). Each write becomes the same command the dashboard sends, through the roaster's
control gate: refused when control is off for the roaster or the output is not declared, shaped
to its range and fan floor otherwise. A refusal is answered "server device failure", which
Artisan does not show (its writes do not wait for an answer): the curve not moving is the sign,
and the audit log has the reason.
Writes are your choice: they let a second program command the roaster, and Artisan's sliders know nothing of a profile drive Roastwarden is running. Read-only is the default, and the right one for a screen.
The audit log
Every write, refused or not, is a row: actor modbus, method MODBUS, path
/modbus/holding/<register>, the client's address, the roaster and what it asked for (kind
control; Settings → Audit, GET /api/audit?kind=control). A write while writes are off is
logged with status 403 and "read-only".
Not yet
- One roaster per slave. With two real roasters, set
ROASTWARDEN_MODBUS_DEVICE_IDto the one Artisan should show. - Artisan's START/CHARGE/DROP do not reach Roastwarden, nor Roastwarden's events Artisan: each app keeps its own record. Artisan's event buttons could write a "mark" register later.
- A setpoint slider (Artisan's
writeWord(1,0,{})writes the float the slave takes) is left out: a fluid bed's setpoint belongs to Roastwarden's profile drive. - The setup in Artisan's Machines menu (Artisan asks for the host then): it would be a pull request to Artisan.